Jpp  master_rocky-40-g5f0272dcd
the software that should make you happy
JORCACalibrateMuon.sh
Go to the documentation of this file.
1 #!/bin/zsh
2 #
3 # \author mdejong
4 #
5 script=${0##*/}
6 
7 # ------------------------------------------------------------------------------------------
8 #
9 # Script to run the JCalibrateMuon for ORCA.
10 #
11 # ------------------------------------------------------------------------------------------
12 
13 if [ -z $JPP_DIR ]; then
14  echo "Variable JPP_DIR undefined."
15  exit
16 fi
17 source $JPP_DIR/setenv.sh $JPP_DIR
18 
19 set_variable DEBUG 2
20 set_variable PDF $JPP_DATA/J%p.dat
21 set_variable HISTOGRAM 260 -30.0 +100.0
22 
23 if do_usage $*; then
24  usage "$script <detector file> <input file> <output file> [(calibration file)+]"
25 fi
26 
27 if (( $# < 3 )); then
28  fatal "Wrong number of arguments."
29 fi
30 
31 set_variable DETECTOR $argv[1]
32 set_variable INPUT_FILE $argv[2]
33 set_variable OUTPUT_FILE $argv[3]
34 set_array CALIBRATION $argv[4,-1]
35 
36 PARAMETERS=(
37  TTS_ns 2
38  E_GeV 10.0
39  TMin_ns -50.0
40  TMax_ns +450.0
41  ZMin_m -3.0
42  ZMax_m +9.0
43  R_Hz 7.0e3
44  roadWidth_m 50.0
45  numberOfPrefits 1)
46 
47 timer_start
48 
49 eval JCalibrateMuon \
50  -a $DETECTOR \
51  -f $INPUT_FILE \
52  -o $OUTPUT_FILE \
53  -P $PDF \
54  -@ `make_equation PARAMETERS` \
55  -+${^CALIBRATION} \
56  -c \"$HISTOGRAM\" \
57  -d $DEBUG --!
58 